Houston-area surplus wire buyer · Pickup across Greater HoustonCall or text 951-403-5738

Wire type · UF-B

Sell UF-B Cable in Houston

Houston Wire Buyers buys new, unused and reusable surplus UF-B underground feeder cable throughout Greater Houston. We review solid copper cable in 14 AWG, 12 AWG, 10 AWG, 8 AWG and 6 AWG, including full coils, partial reels and usable cut lengths. Send photos of the jacket print, available footage or weight, and your location for a written offer. Pickup is scheduled at your site; drop-off at our southeast Houston address is by appointment only.

Three stacked reels of black, red and white THHN building wire in a warehouse
Surplus wire and cable from Houston Wire Buyers

SPECUF-B spec sheet

Example UF-B jacket print: UF-B 600V 10-2 WITH GROUND SUNLIGHT RESISTANT UF-B 600V 10-2 WITH GROUND SUNLIGHT RESISTANT EXAMPLE PRINT LEGEND · UF-B Photograph this line on your reel; it tells us size, type, voltage and maker.
UF-B Underground Feeder Cable: typical construction
Voltage rating600 V
ConductorSolid copper with bare ground
ConstructionConductors molded in a solid gray PVC jacket
StandardsUL 493; NEC Article 340
Example printUF-B 600V 10-2 WITH GROUND SUNLIGHT RESISTANT

Sizes we buy in UF-B

01Identify UF-B Cable by Its Jacket Print

UF-B is underground feeder cable used for direct-burial applications such as outbuilding feeds, pumps and landscape circuits. The construction described here has solid copper conductors and a bare ground molded into a solid gray PVC jacket. Its voltage rating is 600 V, with UL 493 and NEC Article 340 as the applicable product and installation references.

A typical marking reads “UF-B 600V 10-2 WITH GROUND SUNLIGHT RESISTANT.” UF-B identifies the cable type; 600V is the voltage rating. The 10-2 designation identifies 10 AWG conductors and two insulated conductors, with the bare grounding conductor indicated separately by “WITH GROUND.” “SUNLIGHT RESISTANT” describes the marked jacket property.

Gray color alone does not establish cable type. Photograph readable markings and any packaging label; our guide to reel tags and jacket print explains what information to capture. Have a licensed electrician or engineer resolve installation questions.

02Sizes, Conductor Configurations and Packaging We Buy

We review UF-B in 14 AWG, 12 AWG, 10 AWG, 8 AWG and 6 AWG. If you have surplus 12 AWG wire or 10 AWG wire, identify it specifically as UF-B rather than sending only the gauge. Cable type and conductor configuration both affect whether the material matches current demand.

Include the complete conductor-count marking from the jacket or package. For cable marked “WITH GROUND,” report that wording along with the size and count rather than counting the bare ground as another insulated conductor. If several configurations are mixed together, separate them in your inventory.

UF-B is usually sold in 50 to 1,000 ft coils. We also review full reels, partial reels, cut lengths and boxed material. Original labels help, but loose cable can still be reviewed when its markings, condition and available length are clear. Describe each continuous length separately.

03What Makes Surplus UF-B Worth More Than Scrap

Reusable UF-B is usually worth more than its scrap, or melt, value because a buyer can use the cable as cable rather than recover only its copper. Clear identification, useful continuous footage and intact insulation make that distinction important. An unused coil with its label provides a different resale opportunity than tangled, unidentified remnants.

Our review considers the copper market, cable type and current demand, size, footage, packaging condition, manufacturer, date code, quantity and pickup logistics. Copper content matters, but it is not the only factor. A weight-only description leaves out information that can support a reusable-material offer.

As UF cable buyers, we focus on material that can remain in service as cable. Burned cable, heavily damaged jacket and short offcuts may be better suited to scrap. Tell us about defects before scheduling; we will identify what appears reusable rather than treat every pile as equivalent inventory.

04Check Ends, Jacket Condition and Labels Before Selling

Before sending photos, look over each coil or reel without stripping the jacket or disturbing sound packaging. Show the material as it sits, then add close-ups of the markings and any questionable areas. A useful condition checklist includes:

  • Whether cut ends are sealed or exposed, and whether moisture or dirt is visible.
  • Cuts, crushing, abrasion, heat damage or other jacket defects.
  • Coil organization and reel condition, including damaged flanges or loose winding.
  • Manufacturer labels, jacket print and any readable date code.
  • Whether the footage is labeled, measured or estimated.

A sealed end helps describe storage condition; it does not prove that the entire cable is undamaged. Likewise, an older date code alone does not tell the whole story. Explain whether the cable was stored indoors, outdoors or removed from an installation. Do not hide damaged sections inside a coil; showing them helps us assess the usable material accurately.

05Who Typically Has Surplus UF-B in Greater Houston

UF-B surplus can come from electrical contractors, general contractors, homebuilders, electrical distributors and property maintenance teams. Common situations include canceled work, revised routing, unused project stock and leftover coils after outbuilding, pump or landscape circuit work. The important question is whether the remaining cable is identifiable and reusable.

For electrical contractors, separating UF-B from indoor building cable and individual conductors makes the inventory easier to review. Distributors and builders should retain package labels where available. Maintenance teams should distinguish unused stock from cable pulled out of service and describe the history of each lot.

We serve Greater Houston only: Harris, Fort Bend, Montgomery, Brazoria, Galveston, Chambers and Waller counties. Our location is in southeast Houston’s Mayfair area, near I-45 and I-610. Send the actual pickup location with your inventory so we can account for access and transportation when preparing an offer.

06How to Sell UF-B Cable and Get a Written Offer

Start by texting 951-403-5738 or emailing industrial832@gmail.com. Send overall photos, close-ups of reel tags or jacket print, footage or weight, and the material’s location. Include sizes, conductor configurations, packaging and known damage. If footage is uncertain, say so rather than presenting an estimate as a measured length.

We review that information and provide a written offer. After that, we schedule pickup at your site or an appointment for drop-off. We verify the material on site, and payment follows the written offer. Review the offer before scheduling so the material description and payment terms are clear.

Drop-off is at 6402 McGrew St, Houston, TX 77087, by appointment only; call first. If you want to sell underground feeder cable along with other surplus inventory, identify each type separately. Use our offer request page to organize the details for review.

07UF-B Compared With Other Surplus Cable Types

Do not group every building cable under the same description. UF-B’s molded jacket and underground feeder identification distinguish it from NM-B cable, commonly called Romex. NM-B is intended for dry-location applications and is not a substitute for direct-burial UF-B. Similar-looking conductor arrangements do not make the two types interchangeable.

MC cable has a metallic armor construction rather than UF-B’s solid gray PVC jacket. Its permitted uses depend on its listing and construction. Identify it separately instead of assuming that armor alone establishes suitability for burial or wet locations.

THHN/THWN-2 wire consists of individually insulated conductors rather than a UF-B cable assembly. Wet-location suitability depends on the actual marking, not a casual description of the wire. For selling purposes, keep these types in separate groups and photograph their labels. For choosing a wiring method, consult a licensed electrician or engineer.

FAQQuestions sellers ask

Should I strip UF-B before asking for an offer?

No. Leave potentially reusable UF-B intact for review. Removing its molded jacket destroys the cable assembly and removes markings that help establish its identity. If you have already stripped some material, keep it separate and describe it accurately. We focus on reusable wire and cable, not simply recovered copper.

Can I request a review if the original coil wrapper is missing?

Yes. Missing packaging does not automatically rule out a review. Send clear jacket-print photos and explain what you know about the cable’s source and remaining length. Do not attach a label from another coil or assume nearby packaging belongs to it. Accurate identification matters more than making loose stock look factory-packaged.

Will you buy UF-B that was previously buried?

Previously buried cable needs a condition review; its original direct-burial designation does not establish its present condition. Tell us it was removed from service and show exposed ends, jacket damage and any affected areas. We do not assume recovered cable is reusable, and heavily damaged material may be better suited to scrap.

Can you confirm whether my UF-B is suitable for a pump circuit?

We can review the markings to identify material for a surplus purchase, but that is not installation approval. A pump circuit requires an assessment of the equipment, load, wiring method and site conditions. Have a licensed electrician or engineer determine suitability under the applicable requirements before using surplus cable.

Are you Houston Wire & Cable Company?

No. Houston Wire Buyers is not affiliated with Houston Wire & Cable Company or any manufacturer. We buy reusable surplus wire and cable in Greater Houston. When contacting us about UF-B, use 951-403-5738 or industrial832@gmail.com, and confirm an appointment before bringing material to our McGrew Street address.

Read us the reel tag. We'll tell you what it's worth as wire, not as scrap.

Call now951-403-5738